RFI-01FREE CONTRACTOR UTILITY
Construction RFI Log Generator
Professional commercial RFI register with automated sequential numbering, review deadline tracking, overdue aging alerts, and instant Excel exports.
100% In-Memory Execution
Zero cloud storage of project numbers, pricing, or documents. Data stays strictly inside your browser.
Project Specification & Header Data
Header metadata prints cleanly on exported reports and formal submittal covers.
Privacy Note: When “Save on This Device” is clicked, data is saved strictly inside this browser's localStorage (
bdp_tool_rfi_log). If using a public or shared computer, click “Clear Data” when finished. No data is ever transmitted to remote cloud servers.OFFICIAL CONSTRUCTION RFI REGISTER
Metropolitan Medical Pavilion • Job #2026-BD-104
Contractor: BuildDesk Commercial Partners
Architect/Engineer: Apex Design & Engineering Group
Log Date: 2026-10-25
Total RFIs4
Open / In Review3
Closed / Resolved1
Overdue (>7d)2
Cost Impacts1
Threshold:
| RFI # | Discipline | Drawing / Spec | Subject & Question | Reviewer | Sent | Aging | Status | Impact | Actions |
|---|---|---|---|---|---|---|---|---|---|
| RFI-001 | Structural | S-102 03 30 00 | Foundation dowel placement at Grid B-4 conflict Plumbing rough-in conflicts with 24-inch spread footing rebar cage at Grid B-4. Requesting structural engineer approval for relocated dowels. Official Response: Approved per Structural Sketch SK-04. Offset dowels 6 inches North. | Apex Structural Lead | 2026-10-10 | 5d | Closed | Cost: No | |
| RFI-002 | Architectural | A-501 08 11 00 | Door 104B frame throat dimension discrepancy Partition type P-2 on Sheet A-101 indicates 6-inch CMU with 7/8 furring, but Door Schedule on A-501 specifies a 5-3/4 throat frame. Please clarify required frame throat depth. | Project Architect | 2026-10-12 | 13d | Open | Cost: TBD | |
| RFI-003 | Electrical | E-201 26 51 00 | Luminaire Type F-4 ceiling suspension conflict Fixture Type F-4 continuous linear pendants intersect main supply ductwork in Corridor 102. Requesting 8-inch offset or remote ballast approval. Official Response: Under evaluation with mechanical coordination team. | MEP Engineer of Record | 2026-10-05 | 20d | Under Review | Cost: Yes | |
| RFI-004 | Mechanical | M-301 23 31 00 | RTU-2 roof curb seismic tie-down detail clarification Specification 23 05 48 requires IBC seismic isolation clips, but detail 4/M-301 shows direct weld to structural curb. Confirm tie-down attachment spec. | Structural / Mechanical Engineers | 2026-10-20 | 5d | Open | Cost: No |
NEED DEDICATED PRECONSTRUCTION SUPPORT?
Managing Complex Plan Revisions or Disputed RFIs?
BuildDesk Partners conducts independent Drawing Revision Audits and sheet-by-sheet comparative audits to detect scope changes, unclouded revisions, and specification deltas before they impact your job costs.